ATEX-Pressure transmitter TST-SMX 2
Intrinsically safe pressure transmitter with ATEX approval
Ex approval for Zone 0: II 1G Ex ia IIB T4 or II 1G Ex ia IIC T4
Ex approval for Zone 1: II 2G Ex ia IIC T4
IECEx approval acc. Ex ia IIB T4 Ga or Ex ia IIC T4 Gb (Ga with M12x1)
Measuring ranges from +10 ... +600 mbar to 0 … +1000 bar
Output signal 4 … 20 mA
product description ATEX-Pressure transmitter TST-SMX 2
TIVAL Sensors TST-SMX 2 pressure transmitters are designed for use in potentially explosive atmospheres.
The TST-SMX 2 pressure transmitter with ATEX or IECEx approval is available for this purpose.
The ATEX approval is available for Zone 0 acc. II 1G Ex ia IIB T4 or II 1G Ex ia IIC T4 and for Zone 1 acc. II 2G Ex ia IIC T4, the IECEx approval is available acc. to Ex ia IIB T4 Ga or Ex ia IIC T4 Gb (Ex ia IIC T4 Ga only with M12x1 connector). The measuring range can be freely selected, starting with the small millibar measuring range of +10 ... +600 mbar up to a measuring range of 0 ... +1000 bar. As an output signal, the TST-SMX 2 has a 4 ... 20 mA analog output in 2-wire technology.
Standard pressure ranges TST-SMX 2 Individual pressure ranges on request |
|||||||||||||
Measuring range | P(mbar) | 10 | 16 | 20 | 25 | 40 | 60 | 100 | 160 | 200 | 250 | 400 | 600 |
Overpressure | P(mbar) | 50 | 80 | 100 | 125 | 200 | 300 | 500 | 800 | 1000 | 1000 | 1000 | 1000 |
Bursting pressure | P(mbar) | 150 | 240 | 300 | 375 | 600 | 900 | 1500 | 2400 | 3000 | 3000 | 3000 | 3000 |
Measuring range | P(bar) | 1,0 | 1,6 | 2,0 | 2,5 | 4,0 | 6,0 | 10,0 | 16,0 | 20 | 25 | ||
Overpressure | P(bar) | 6 | 6 | 6 | 10 | 10 | 20 | 20 | 40 | 40 | 100 | ||
Bursting pressure | P(bar) | 9 | 9 | 9 | 15 | 15 | 30 | 30 | 60 | 60 | 150 | ||
Measuring range | P(bar) | 40 | 60 | 100 | 160 | 200 | 250 | 400 | 600 | 100 | |||
Overpressure | P(bar) | 100 | 200 | 200 | 400 | 400 | 750 | 750 | 840 | 1200 | |||
Bursting pressure | P(bar) | 150 | 300 | 300 | 600 | 600 | 1000 | 1000 | 1050 | 1500 |
Technical data | ATEX-Pressure transmitter TST-SMX 2 | |
Electrical parameters | ||
Output signal Operating voltage UB Permitted max. load RA |
4 ... 20 mA (2-wire) 20 ... 27 V DC RA ≤ (UB - 16 V) / 20 mA, at least 100 Ω |
|
Response time (10 ... 90 %) | < 1 ms | |
Accuracy specifications | Pressure range 0 ... +1000 bar | Pressure range +10 ... + 600 mbar |
BFSL | ≤± 0,25 % FS | ≤± 0,50 % FS |
Total error at RT |
≤± 0,50 % FS * Optionally available with increased measuring accuracy of ≤± 0.25 % FS |
≤± 1,00 % FS * Optionally available with increased measuring accuracy of ≤± 0.50 % FS |
* Including nonlinearity, hysteresis, zero point and full scale error (according to IEC 61298-2). |
||
Stability per year | ≤± 0,20 % FS | ≤± 0,40 % FS |