Digital contact gauge TST-PM 82
82 mm stainless steel housing, process connection on housing bottom
Dry ceramic measuring cell
Analog output and one or two PNP transistor switching outputs
Measuring ranges from 0 ...+25 mbar to 0... +250 bar
3-digit LED display with 14 mm digit height
product description Digital contact gauge TST-PM 82
The digital contact pressure gauge TST-PM 82 measures and monitors pressures in measuring ranges from 0 ... +25 mbar to 0 ... +250 bar and shows the measured value in the display. The total measurement error at room temperature is ≤ ± 0.5% FS. The G 1/2 "B process connection and the M12x1 electrical connection are located on the bottom of the housing. The TST-PM 82 can be equipped with one or two PNP transistor switching outputs. The t switching point values of the PNP transistor switching outputs can be quickly and easily selected by using the control buttons of the TST-PM 82. The switching status of the outputs is indicated by LED’s. The detected pressure can also be output as an analogue output signal (0 ... 20 mA, 3-wire or 4 ... 20 mA, 2-wire or 0 … 10 V DC, 3-wire).
- 3-digit LED display
- 14 mm digit height
- 1 or 2 controllable transistor switching outputs, DC PNP, max. 200 mA
- Dry ceramic measuring cell
- Measuring ranges from 0 ... +25 mbar up to 0 ... +250 bar
- Optional analogue output, 0 ... 20 mA, 3-wire or 4 ... 20 mA, 2-wire or 0 ... 10 V DC, 3-wire
- Temperature range -25 ... +80 °C
- Process temperature -25 ... +100 °C
- 82 mm stainless steel housing
- On request also available with all common process connections
Standard pressure ranges TST-PM 82 Gauge pressure measuring ranges, absolute pressure measuring ranges on request |
||||||||
Measuring range
Overpressure |
mbar bar |
-20 ... 20* -0,3 / 4 |
25 -0,3 / 4 |
40 -0,3 / 4 |
50 -0,3 / 4 |
60 -0,3 / 4 |
-100 ... 100 -1 / 2 |
100 -1 / 2 |
Measuring range Overpressure |
mbar bar |
160 -1 / 2 |
200 -1 / 2 |
250 -1 / 2 |
400 -1 / 2 |
500 -0,2 / 2 |
600 -0,2 / 2 |
|
Measuring range Overpressure |
bar bar |
1 -1 / 4 |
1,6 -1 / 4 |
2 -1 / 4 |
2,5 -1 / 10 |
4 -1 / 10 |
5 -1 / 10 |
6 -1 / 20 |
Measuring range Overpressure |
bar bar |
10 -1 / 40 |
16 -1 / 40 |
20 -1 / 40 |
25 -1 / 100 |
40 -1 / 100 |
50 -1 / 100 |
60 -1 / 200 |
Measuring range Overpressure |
bar bar |
100 -1 / 200 |
160 -1 / 400 |
250 -1 / 600 |
-1 ... 1 -1 / 4 |
-1 ... 3 -1 / 10 |
-1 ... 5 -1 / 10 |
-1 ... 9 -1 / 40 |
* the total measurement error for this measuring range is ≤± 1 % FS |