- Digital display for DIN rail mounting with configurable measuring range
- Input for standard signals (0/4 ... 20 mA, 0/2 ... 10 V DC)
- Measuring range individually programmable
- Basic accuracy 0.1% ± 1 digit
- Predetermined units: mV, V, mA, A, Ω, kΩ, μS / cm, mS / cm, °C, °F, min-1, U/min, bar, mbar, hPa, mm, cm, m, %, °, l, Ltr / Min, m³, m³ / h, ppm, own units programmable
- simulator function
- Automatic wire break detection in the measuring circuit
- Programmable behavior in case of error, analog output open or closed, alarm outputs min. or max. switching behavior
- Integrated transmitter power supply 24 V, max. 30 mA
- Optionally with up to 4 alarm outputs (relay changer)
- Optionally a galvanically isolated analogue output (0/4 ... 20 mA, 0/2 ... 10 V DC)
- Galvanic isolation between input / output / auxiliary voltage
The digital display TS-MR 50 is used to monitor measured values. These must be available as standard signals 0/4 ... 20 mA or 0/2 ... 10 V DC and fed to the input of the device. Display range and units for the measured value are individually programmable. An integrated transmitter supply allows direct connection of 2- or 3-wire sensors with the following analog outputs: 0/4 ... 20 mA and 0/2 ... 10 V DC. The device offers simple programming, up to 4 programmable alarm outputs (relay changer) and optionally one configurable, galvanically isolated 4 ... 20 mA or 0/2 ... 10 V DC analog output. Minimum and maximum measuring values are stored in the background and displayed.