Pressure and temperature transmitter TST-TPSE
Parallel and independent measurement of pressure and temperature
Temperature measurement with external temperature probe
Media temperature -40 ... +125 °C, Temp. measuring range configurable
Pressure measuring ranges from 0 ... +4 bar to 0 … +600 bar
4 ... 20 mA analogue output signals for pressure and temperature
product description Pressure and temperature transmitter TST-TPSE
The TST-TPSE combi sensor transmitters series is designed for parallel and independent measured value acquisition of pressure and temperature at only one measuring point. For this purpose, the process connection of the proven TIVAL pressure transmitter was additionally equipped with an external stainless steel temperature probe. The length of the temperature probe can be chosen variable, the diameter is 2 mm.
The fully welded, dry stainless steel pressure cell is available for measuring ranges from 0 ... +4 bar to 0 ... +600 bar. The combination sensor is designed for permanent media temperatures of -40 ... + 125 °C. Up to 15 minutes duration a media temperature of -50 ... +200 °C is permissible.
The temperature measuring range can be configured as required within the admissible medium temperature of -40 ... + 125 °C, eg. a measuring range of -50 .... +75 °C.
The measured pressure and temperature values are output as 4 ... 20 mA analog signal. The pressure value can also be executed as 0 ... 10 V DC analogue output. The sensor design with an external temperature sensor enables fast reaktion ans setting times for the measured temperature value of 10 ... 20 seconds, but influences the volume flow of the measuring medium.
The TST-TPSE combination sensor is particularly suitable for thermally dynamic processes in which pressure and temperature are to be measured simultaneously in extremely tight spaces. Since only one mounting position has to be provided for both measured values, it is possible to engineer smaller and more compact and significantly reduce installation and cabling costs.
Standard pressure ranges TST-TPSE Individual pressure ranges on request |
|||||||||
Measuring range | P(bar) | 4 | 6 | 10 | 40 | 60 | 100 | 400 | 600 |
Overpressure | P(bar) | 20 | 20 | 20 | 200 | 200 | 200 | 840 | 840 |
Bursting pressure | P(bar) | 30 | 30 | 30 | 300 | 300 | 300 | 1050 | 1050 |
Technical data | Pressure and temperature transmitter TST-TPSE |
|
Electrical parameters | TST-TPSE - Output signal for pressure |
|
Output signal Operating voltage UB Permitted max. load RA Recommended max. load resistor RL |
4 ... 20 mA (2- or 3-wire) 9 ... 32 V DC RA > (UB - 9 V) / 20 mA |
0 ... 10 V DC (3-wire) 12 ... 32 V DC RL > 5 kΩ |
Response time (10 ... 90 %) | < 1 ms | < 1 ms |
TST-TPSE - Output signal for temperature |
||
Output signal Operating voltage UB Permitted max. load RA |
4 ... 20 mA (2-wire) 9 ... 32 V DC RA > (UB - 9 V) / 20 mA |
|
Response time (10 ... 90 %) | 10 ... 20 s | 10 ... 20 s |
Dielectric strength | 350 V DC | 350 V DC |
Accuracy specifications | TST-TPSE - Output signal for pressure |
|
BFSL | ≤± 0,125 % FS | ≤± 0,125 % FS |
Total error at RT |
≤± 0,50 % FS - including nonlinearity, hysteresis, zero point and full scale error (according to IEC 61298-2). Optionally available with increased pressure measuring accuracy of ≤± 0.25 % FS |
|
Stability per year | ≤± 0,10 % FS | ≤± 0,10 % FS |
Accuracy specifications | TST-TPSE - Output signal for temperature |
|
BFSL | ≤± 0,125 % FS | ≤± 0,125 % FS |
Total error at RT |
≤± 0,50 % FS - including nonlinearity, hysteresis, zero point and full scale error (according to IEC 61298-2). |
|
Stability per year | ≤± 0,10 % FS | ≤± 0,10 % FS |