Pressure and temperature transmitter TST-TPSI
Parallel and independent measurement of pressure and temperature
Temperature measurement with internal temperature sensor
Media temperature -40 ... +125 °C, Temp. measuring range -50 ... +150 °C
Pressure measuring ranges from 0 ... +1 bar to 0 … +1000 bar
Fully welded stainless steel measuring cell and stainless steel housing
product description Pressure and temperature transmitter TST-TPSI
The combination sensors of the TST-TPSI transmitters series have been developed for the parallel and independent measured value acquisition of pressure and temperature at only one measuring point. For this purpose, the proven TIVAL pressure transmitter with fully welded, dry stainless steel measuring cell and compact stainless steel housing has been supplemented by an internal temperature sensor. The additional temperature sensor is integrated into the process connection. In addition to accurate measurement of pressure in pressure ranges from 0 ... +1 bar to 0 ... +1000 bar, the temperature within a measuring range of -40 ... +125 °C can be measured simultaneously at the same mounting position. For a short time, media temperatures of -50 ... +150 °C are permissible, which therefore correspond to the complete measuring range.
The measured pressure and temperature values can either be selected as a ratiometric output signal (pressure signal 0.5 ... 4.5 V DC ratiometric / temperature signal 0.25 ... 4.75 ratiometric) or as a combination of 0 ... 10 V DC analog output for the pressure and 0.25 ... 4.75 V DC output for the temperature. The fact that the the temperature sensor is integrated in the process connection allows an additional meausurement of the temperature that does not affect the volume flow of the medium. But this type of construction design requires a longer response time for the measured temperature value.
The TST-TPSI combi sensor is especially suitable for thermally inert processes in which pressure and temperature have to be measured simultaneously in extremely tight spaces. Since only one mounting position has to be provided for both measured values, it is possible to construct smaller and more compact and significantly reduce installation and cabling costs.
Standard pressure ranges TST-TPSI Individual pressure ranges on request |
|||||||||||
Measuring range | P(bar) | 1,0 | 1,6 | 2,0 | 2,5 | 4,0 | 6,0 | 10,0 | 16,0 | 20 | 25 |
Overpressure | P(bar) | 6 | 6 | 6 | 10 | 10 | 20 | 20 | 40 | 40 | 100 |
Bursting pressure | P(bar) | 9 | 9 | 9 | 15 | 15 | 30 | 30 | 60 | 60 | 150 |
Measuring range | P(bar) | 40 | 60 | 100 | 160 | 200 | 250 | 400 | 600 | 1000 | |
Overpressure | P(bar) | 100 | 200 | 200 | 400 | 400 | 750 | 750 | 840 | 1200 | |
Bursting pressure | P(bar) | 150 | 300 | 300 | 600 | 600 | 1000 | 1000 | 1050 | 1500 |
Technical data | Pressure and temperature transmitter TST-TPSI |
|
Electrical parameters | TST-TPSI - Output signal for pressure |
|
Output signal Operating voltage UB Recommended max. load resistor RL |
0,5 ... 4,5 V DC ratiometric 5 V DC ± 10 % RL > 4,7 kΩ |
0 ... 10 V DC (3-wire) 12 ... 32 V DC RL > 5 kΩ |
Response time (10 ... 90 %) | < 1 ms | < 1 ms |
TST-TPSI - Output signal for temperature Temperature measurement range: -50 ... +150 °C |
||
Output signal Operating voltage UB Recommended max. load resistor RL |
0,25 ... 4,75 V DC ratiometric* 5 V DC ± 10 % RL > 4,7 kΩ |
0,25 ... 4,75 V DC (2-Leiter) 5 V DC ± 10 % RL > 4,7 kΩ |
* Temperature signal only ratiometric, if pressure signal is also ratiometric | ||
Response time (10 ... 90 %) | 120 s | 120 s |
Dielectric strength | 350 V DC | 350 V DC |
Accuracy specifications | TST-TPSI - Output signal for pressure | |
BFSL | ≤± 0,125 % FS | ≤± 0,125 % FS |
Total error at RT |
≤± 0,50 % FS - including nonlinearity, hysteresis, zero point and full scale error (according to IEC 61298-2). Optionally available with increased pressure measuring accuracy of ≤± 0.25 % FS |
|
Stability per year | ≤± 0,10 % FS | ≤± 0,10 % FS |
Accuracy specifications | TST-TPSI - Output signal for temperature | |
BFSL | ≤± 0,125 % FS | ≤± 0,125 % FS |
Total error at RT |
≤± 0,50 % FS - including nonlinearity, hysteresis, zero point and full scale error (according to IEC 61298-2). |
|
Stability per year | ≤± 0,10 % FS | ≤± 0,10 % FS |