Pressure transmitter TST 10... / 20...

Pressure transmitter TST 10... / 20...

Measuring ranges from -1 ... 0 bar to 0 ... +1000 bar

Output signal 4 ... 20 mA (2- or 3-wire) or 0 ... 10 V (3-wire)

Dry stainless steel measuring cell and compact stainless steel housing

Media temperature -40 … +125 °C

Available as relative pressure or absolute pressure transmitter

product description Pressure transmitter TST 10... / 20...

The pressure transmitters of the TST 10 ... / 20 ... series are designed for the numerous measuring tasks and requirements in mechanical engineering, in hydraulics and pneumatics, in plant construction and in automation technology. Long-term reliability, high measurement accuracy and a robust and compact stainless steel housing are the basic features of TIVAL Sensors TST 10 ... / 20 ... pressure transmitters.

The measuring range of the TIVAL TST 10 ... / 20 ... pressure transmitter can be set individually and continuously in ranges from -1 ... 0 bar to 0 ... +1000 bar. As an output signal, all currently used 2- or 3-wire analog output signals are available for selection. Process port and electrical connection can be combined customer-specifically from the current versions of the present MCR technology. Further additional options such as increased measurement accuracy of 0.25% FS, connection assignments according to customer specifications or an increased IP protection class allow the TIVAL TST 10 ... / 20 ... to be adapted to all industrial measurement requirements.

The use of a "dry", fully welded stainless steel measuring cell leads to high media compatibility and suitability. In addition, since no internal transmission medium is necessary, the TIVAL Sensors TST 10 ... / 20 ... pressure transmitter can be used in many different ways in water technology.


Standard pressure ranges TST 10... / 20...
Individual pressure ranges on request
Measuring range P(bar) 1,0 1,6 2,0 2,5 4,0 6,0 10,0 16,0 20 25
Overpressure P(bar) 6 6 6 10 10 20 20 40 40 100
Bursting pressure P(bar) 9 9 9 15 15 30 30 60 60 100
Measuring range P(bar) 40 60 100 160 200 250 400 600 1000  
Overpressure P(bar) 100 200 200 400 400 750 750 840 1200  
Bursting pressure P(bar) 150 300 300 600 600 1000 1000 1050 1500  




Technical data Pressure transmitter TST 10... / 20...
Electrical parameters TST 10... TST 20...
Output signal
Operating voltage UB
Permitted max. load RA
Recommended max. load resistor RL
4 ... 20 mA (2- or 3-wire)
9 ... 32 V DC
RA ≤ (UB - 9 V) / 20 mA

0 ... 10 V DC (3-wire)
12 ... 32 V DC

RL > 5 kΩ
Response time (10 ... 90 %) < 1 ms < 1 ms
Accuracy specifications    
BFSL ≤± 0,15 % FS ≤± 0,15 % FS
Total error at RT


≤± 0,50 % FS - including nonlinearity, hysteresis, zero point and full scale error
(according to IEC 61298-2).
Optionally available with increased measuring accuracy of ≤± 0.25 % FS
Stability per year ≤± 0,10 % FS