Pressure transmitter TST-K121

Pressure transmitter TST-K121

Measuring ranges from 0 ... +40 mbar to 0 ... +250 bar

Output signal 4 ... 20 mA (2-wire) or 0 ... 10 V DC (3-wire)

Dry ceramic measuring cell and robust stainless steel housing

Vacuum-proof and high overload resistance

Total measurement error ≤ 0.2 % FS

product description Pressure transmitter TST-K121

The pressure transmitters type TST-K121 have got a vacuum-proof, dry ceramic measuring cell which delivers precise and reliable measuring results even at very small measuring ranges, starting from 0 ... +40 mbar. The measuring range can be freely calibrated from 0 ... +40 mbar up to 0 ... +250 bar and is characterized by a high overload resistance. Most pressure ranges are also available as absolute pressure sensor. The permissible media temperature is -40 ... +100 °C. 4 ... 20 mA (2-wire) or 0 ... 10 V DC (3-wire) are available as analogue output signal. The TST-K121 is available with several common process connections and connection plugs. The pin assignment of the connection plug can be freely selected.



Standard pressure ranges TST-K121 for gauge pressure measurement
Absolute pressure measurement or individual pressure ranges on request
Measuring range P(mbar) 40* 50* 60* 100 160 200 250
Overpressure P(bar) -0,3 / +4 -0,3 / +4 -0,3 / +4 -0,3 / +4 -0,6 / +5 -1 / +6 -1 / +6
Measuring range P(bar) 0,4 0,5 0,6 1,0 1,6 2,0 2,5
Overpressure P(bar) -1 / +6 -1 / +6 -1 / +10 -1 / +10 -1 / +18 -1 / +18 -1 /+18
Measuring range P(bar) 4,0 5,0 6,0 10 16 20 25
Overpressure P(bar) -1 / +25 -1 / +40 -1 / +40 -1 / +40 -1 / +40 -1 / +40 -1 / +40
Measuring range P(mbar) -100 ... 0 -100 ... +100 -200 ... 0 -200 ... +200
Overpressure P(bar) -0,3 / +4 -1 / +6 -1 / +6 -1 / +6
Measuring range P(bar) -1 ... +1 -1 ... +3 -1 ... +5 -1 ... +9 -1 ... +15 -0,8 ... +1,2
Overpressure P(bar) -1 / +10 -1 / +25 -1 / +40 -1 / +40 -1 / +40 -1 / +10


* the total measurement error for this measuring range is ≤± 0.5 % FS

Technical data Pressure transmitter TST-K121
Electrical parameters  
Output signal
Operating voltage UB
Permitted max. load RA
Recommended max. load resistor RL
4 ... 20 mA (2-wire)
9 ... 30 V DC
RA ≤ (UB - 9 V) / 20 mA

0 ... 10 V DC (3-wire)
12 ... 32 V DC

RL > 5 kΩ
Response time (10 ... 90 %) < 200 ms < 200 ms
Accuracy specifications  
Total error at RT

≤± 0.20 % FS - including nonlinearity, hysteresis, zero point and full scale error
(according to IEC 61298-2).
Stability per year ≤± 0.15 % FS