Pressure transmitter TST-SiAl

Pressure transmitter TST-SiAl

Measuring ranges from 0 ... +10 mbar to 0 … +40 bar

Output signal 4 ... 20 mA (2- or 3-wire) or 0 ... 10 V (3-wire)

Media temperature -40 … +85 °C

Compact and robust stainless steel housing

High reliability

product description Pressure transmitter TST-SiAl

Pressure transmitters of the TST-SiAl series are used in all measuring tasks in which liquids and non-aggressive gases are to be measured accurately and reliably even in very small millibar ranges. Examples are the ventilation technology, the level monitoring of small containers, the food industry or in general in plant construction, automation technology or other industrial applications. The TST-SiAl uses a silicon measuring cell which is suitable for media temperatures from -40 to + 85 ° C. Output signal, process connection and electrical connection can be flexibly combined and selected from the customary market variants.

 

Standard pressure ranges TST-SiAl 10.../ 20...
Individual pressure ranges on request
Measuring range P(mbar) 10 16 20 25 40 60 100 160
Overpressure P(mbar) 300 300 300 300 300 300 300 300
Bursting pressure P(mbar) 500 500 500 500 500 500 500 500
Measuring range P(bar) 0,2 0,25 0,4 0,6 1,0 1,6 2,0 2,5
Overpressure P(bar) 0,3 2,0 2,0 2,0 2,0 6,0 6,0 6,0
Bursting pressure P(bar) 0,5 3,0 3,0 3,0 3,0 9,0 9,0 9,0
Measuring range P(bar) 4,0 6,0 10,0 16 20 25 40  
Overpressure P(bar) 10 20 20 40 40 100 100  
Bursting pressure P(bar) 15 30 30 60 60 150 150  




Technical data Pressure transmitter TST-SiAl
Electrical parameters TST-SiAl 10...
TST-SiAl 20...
Output signal
Operating voltage UB
Permitted max. load RA
Recommended max. load resistor RL
4 ... 20 mA (2- or 3-wire)
10 ... 32 V DC
RA ≤ (UB - 9 V) / 20 mA

0 ... 10 V DC (3-wire)
12 ... 32 V DC

RL > 5 kΩ
Response time (10 ... 90 %) < 1 ms < 1 ms
Dielectric strength 350 V DC 350 V DC
Accuracy specifications  
BFSL ≤± 0,25 % FS ≤± 0,25 % FS
Total error at RT


≤± 1,0 % FS - including nonlinearity, hysteresis, zero point and full scale error
(according to IEC 61298-2).
Optionally available with increased measuring accuracy of ≤± 0.50 % FS
Stability per year ≤± 0,1 % FS