Pressure transmitter TST-SiAl
Measuring ranges from 0 ... +10 mbar to 0 … +40 bar
Output signal 4 ... 20 mA (2- or 3-wire) or 0 ... 10 V (3-wire)
Media temperature -40 … +85 °C
Compact and robust stainless steel housing
High reliability
product description Pressure transmitter TST-SiAl
Pressure transmitters of the TST-SiAl series are used in all measuring tasks in which liquids and non-aggressive gases are to be measured accurately and reliably even in very small millibar ranges. Examples are the ventilation technology, the level monitoring of small containers, the food industry or in general in plant construction, automation technology or other industrial applications. The TST-SiAl uses a silicon measuring cell which is suitable for media temperatures from -40 to + 85 ° C. Output signal, process connection and electrical connection can be flexibly combined and selected from the customary market variants.
Standard pressure ranges TST-SiAl 10.../ 20... Individual pressure ranges on request |
|||||||||
Measuring range | P(mbar) | 10 | 16 | 20 | 25 | 40 | 60 | 100 | 160 |
Overpressure | P(mbar) | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 |
Bursting pressure | P(mbar) | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
Measuring range | P(bar) | 0,2 | 0,25 | 0,4 | 0,6 | 1,0 | 1,6 | 2,0 | 2,5 |
Overpressure | P(bar) | 0,3 | 2,0 | 2,0 | 2,0 | 2,0 | 6,0 | 6,0 | 6,0 |
Bursting pressure | P(bar) | 0,5 | 3,0 | 3,0 | 3,0 | 3,0 | 9,0 | 9,0 | 9,0 |
Measuring range | P(bar) | 4,0 | 6,0 | 10,0 | 16 | 20 | 25 | 40 | |
Overpressure | P(bar) | 10 | 20 | 20 | 40 | 40 | 100 | 100 | |
Bursting pressure | P(bar) | 15 | 30 | 30 | 60 | 60 | 150 | 150 |
Technical data | Pressure transmitter TST-SiAl | |
Electrical parameters | TST-SiAl 10... |
TST-SiAl 20... |
Output signal Operating voltage UB Permitted max. load RA Recommended max. load resistor RL |
4 ... 20 mA (2- or 3-wire) 10 ... 32 V DC RA ≤ (UB - 9 V) / 20 mA |
0 ... 10 V DC (3-wire) 12 ... 32 V DC RL > 5 kΩ |
Response time (10 ... 90 %) | < 1 ms | < 1 ms |
Dielectric strength | 350 V DC | 350 V DC |
Accuracy specifications | ||
BFSL | ≤± 0,25 % FS | ≤± 0,25 % FS |
Total error at RT |
≤± 1,0 % FS - including nonlinearity, hysteresis, zero point and full scale error (according to IEC 61298-2). Optionally available with increased measuring accuracy of ≤± 0.50 % FS |
|
Stability per year | ≤± 0,1 % FS |