Electronic pressure switch TST-DS5
Electronic pressure switch in transmitter design
Measuring ranges from 0 ... +0,6 bar to 0 … +2000 bar
NPN or PNP switching output with adjustable switching delay
Media temperature -40 … +125 °C
Compact and robust stainless steel housing
product description Electronic pressure switch TST-DS5
The compact electronic pressure switch TST-DS5 meets the highest demands in terms of mechanical stress, high stability and media compatibility and is suitable for all demanding industrial applications. The TST-DS5 has a robust stainless steel housing and is overload-proof and protected against short circuits and polarity reversal. Optionally, the TST DS5 is available with increased shock resistance (> 1000 g) and increased vibration resistance > 30 g to meet the increased requirements in automotive technology and railway applications.
The TST-DS5 is available with a PNP or NPN switching output. The switching output can be executed as a NO or NC function, an ON or OFF switching delay can also be implemented. Switch point and switch-off point or hysteresis can be freely selected and must be defined when ordering. The total measurement error at room temperature is ≤0.5% FS of the pressure range.
The electronic pressure switch TST-DS5 is available with numerous process connections and electrical connection variants.
These and other technical details of the electronic pressure switch TST-DS5 can be found in the data sheet.
Standard pressure ranges Electronic pressure switch TST-DS5 |
||||||||||||
Gauge pressure |
||||||||||||
Measuring range | P(bar) | 0,6 | 1,0 | 1,6 | 2,0 | 2,5 | 4,0 | 6,0 | 10 | 16 | 20 | 25 |
Overpressure | P(bar) | 6 | 6 | 6 | 6 | 6 | 10 | 20 | 20 | 40 | 40 | 100 |
Bursting pressure | P(bar) | 9 | 9 | 9 | 9 | 9 | 15 | 30 | 30 | 60 | 60 | 150 |
Measuring range | P(bar) | 40 | 60 | 100 | 160 | 200 | 250 | 400 | 600 | 1000 | 1600* | 2000* |
Overpressure | P(bar) | 100 | 200 | 200 | 400 | 400 | 750 | 750 | 840 | 1200 | 2400 | 2400 |
Bursting pressure | P(bar) | 150 | 300 | 300 | 600 | 600 | 1000 | 1000 | 1500 | 1500 | 3000 | 3000 |
* all measuring ranges with a final measuring value of > 1000 bar require a high-pressure process connection