High-temperature pressure transmitter TST-SKL
For use with higher temperature requirements and in environments with high thermal loads
For media temperatures from -40 ... +180 °C
Cooling section made of stainless steel
Measuring ranges from 0 ... +1 bar to 0 ... +1000 bar
product description High-temperature pressure transmitter TST-SKL
The TST-SKL high-temperature pressure transmitters are designed for applications with temperature requirements above + 125 ° C and for measurement applications in environments with high thermal loads. The high-temperature pressure transmitters are equipped with a stainless steel cooling section mounted infront of of the original sensor process connection, to protect the pressure transmitter's evaluation electronics from the high process temperatures.
This structural adaptation enables the permanent use of the TST-SKL at ambient temperatures of -40 ... +105 ° C and media temperatures of -40 ... +160 ° C. Up to a duration of max. 15 minutes, the pressure measurement is even possible at elevated temperatures up to +180 ° C.
If a measuring task permanently requires media temperatures of more than +160 ° C, there is also the option of detaching the evaluation electronics from the pressure measuring cell by means of a Teflon cable. The electronics can be installed further away from the process, in a cooler environment. In this way, a pressure measurement for processes with even higher media and ambient temperatures can be realized on request.
Standard pressure ranges TST-SKL 10... / 20... Individual pressure ranges on request |
|||||||||||
Measuring range | P(bar) | 1,0 | 1,6 | 2,0 | 2,5 | 4,0 | 6,0 | 10,0 | 16 | 20 | 25 |
Overpressure | P(bar) | 6 | 6 | 6 | 6 | 10 | 20 | 20 | 40 | 40 | 100 |
Bursting pressure | P(bar) | 9 | 9 | 9 | 9 | 15 | 30 | 30 | 60 | 60 | 150 |
Measuring range | P(bar) | 40 | 60 | 100 | 160 | 200 | 250 | 400 | 600 | 1000 | |
Overpressure | P(bar) | 100 | 200 | 200 | 400 | 400 | 500 | 750 | 840 | 1200 | |
Bursting pressure | P(bar) | 150 | 300 | 300 | 600 | 600 | 1000 | 1000 | 1050 | 1500 |
Technical data | High-temperature pressure transmitter TST-SKL 10... / 20... | |
Electrical parameters | TST-SKL 10... | TST-SKL 20... |
Output signal Operating voltage UB Permitted max. load RA Recommended max. load resistor RL |
4 ... 20 mA (2- or 3-wire) 9 ... 32 V DC RA ≤ (UB - 9 V) / 20 mA |
0 ... 10 V DC (3-wire) 12 ... 32 V DC RL > 5 kΩ |
Response time (10 ... 90 %) | < 1 ms | < 1 ms |
Dielectric strength | 350 V DC | 350 V DC |
Accuracy specifications | ||
BFSL | ≤± 0,15 % FS | ≤± 0,15 % FS |
Total error at RT |
≤± 0,50 % FS - including nonlinearity, hysteresis, zero point and full scale error (according to IEC 61298-2). Optionally available with increased measuring accuracy of ≤± 0.25 % FS |
|
Stability per year | ≤± 0,10 % FS | ≤± 0,10 % FS |