Level probe TST-HD 133

Level probe TST-HD 133

Stainless steel housing 1.4404, IP 68, diameter 40 mm

Measuring ranges from 0 ... 40 mbar to 0 ... +60 bar

Total measurement error ≤ 0.2 % FS

On request with PP or PVDF plastic housing

Optionally as intrinsically safe version with ATEX‑approval

product description Level probe TST-HD 133

  • Stainless steel housing 1.4404
  • On request with PP or PVDF plastic housing
  • Measuring ranges from 0 ... 40 mbar to 0 ... +60 bar
  • Total measurement error ≤ 0.2 % FS
  • High overload resistance
  • Optional with ATEX approval acc. Ex II 1G EEx ia IIC T4
  • Suspension cable according to Bg VV-1.12.96 recommendation, suitable for food and drinking water applications
  • Ceramic sensor AL2O3
  • 4 ... 20 mA or 0 ... 10 V DC analog output
  • Optionally available with protective cap

Level probes HD 133 is a hydrostatic pressure sensor for level measurement of liquids. Different housing versions with different process connections are available. Please note the drawings in the data sheet. The housings are made in 1.4404 stainless steel as standard. Plastic housing in PP or PVDF on request. By default, the ceramic measuring cell is mounted with a FKM (Viton) seal.

 

Measuring range

Measuring range in meter of water column (mWS)

Permissible overpressure (bar)

0 ... 40 mbar* 0 … 400 mmWS* -0,3/4
0 ... 50 mbar* 0 … 500 mmWS* -0,3/4
0 ... 60 mbar* 0 … 600 mmWS* -0,3/4
0 ... 100 mbar 0 … 1 mWS -0,3/4
0 ... 160 mbar 0 … 1,6 mWS -0,6/5
0 ... 200 mbar 0 … 2 mWS -1/6
0 ... 250 mbar 0 … 2,5 mWS -1/6
0 ... 0,4 bar 0 … 4 mWS -1/6
0 ... 0,5 bar 0 … 5 mWS -1/6
0 ... 0,6 bar 0 … 6 mWS -1/10
0 ... 1,0 bar 0 … 10 mWS -1/10
0 ... 1,6 bar 0 … 16 mWS -1/18
0 ... 2,0 bar 0 … 20 mWS -1/18
0 ... 2,5 bar 0 … 25 mWS -1/18
0 ... 4,0 bar 0 … 40 mWS -1/25
0 ... 6,0 bar 0 … 60 mWS -1/40
0 ... 10 bar 0 … 100 mWS -1/40
0 ... 16 bar 0 … 160 mWS -1/40
0 ... 20 bar 0 … 200 mWS -1/40
0 ... 25 bar 0 … 250 mWS -1/40
0 ... 40 bar 0 … 400 mWS -1/60
0 ... 60 bar 0 … 600 mWS -1/100

*
the total measurement error for this measuring range is ≤± 0.5 % FS