Pressure transmitter
Pressure transmitter from TIVAL Sensors GmbH
Measuring ranges from -1 ... 0 bar to 0 ... +1000 bar
Output signal 4 ... 20 mA (2- or 3-wire) or 0 ... 10 V (3-wire)
Dry stainless steel measuring cell and compact stainless steel housing
Media temperature -40 … +125 °C
Available as relative pressure or absolute pressure transmitter
Approved for shipbuilding applications by Germanischer Lloyd
Certified acc. Germanischer Lloyd GL Directive, Chapter 2, Edition 2012
Measuring ranges from -1 ... 0 bar to 0 … +2000 bar
Output signal 4 ... 20 mA (2-wire)
Dry stainless steel measuring cell and compact stainless steel housing
Measuring ranges from > 0 ... +1000 bar to 0 … +4000 bar
High pressure connection with double seal cone
Output signal 4 ... 20 mA (2- or 3-wire) or 0 ... 10 V (3-wire)
Suitable for aggressive liquid or gaseous media
Media temperature -40 … +125 °C
Measuring ranges from 0 ... +10 mbar to 0 … +40 bar
Output signal 4 ... 20 mA (2- or 3-wire) or 0 ... 10 V (3-wire)
Media temperature -40 … +85 °C
Compact and robust stainless steel housing
High reliability
Measuring ranges from 0 ... +100 mbar to 0 ... +2.5 bar
Output signal 4 ... 20 mA (2- or 3-wire) or 0 ... 10 V (3-wire)
Media temperature -20 ... +80 °C
Compact and robust stainless steel housing
High reliability
Intrinsically safe pressure transmitter with ATEX approval
Ex approval for Zone 0: II 1G Ex ia IIB T4 or II 1G Ex ia IIC T4
Ex approval for Zone 1: II 2G Ex ia IIC T4
IECEx approval acc. Ex ia IIB T4 Ga or Ex ia IIC T4 Gb (Ga with M12x1)
Measuring ranges from +10 ... +600 mbar to 0 … +1000 bar
Output signal 4 … 20 mA
Front flush G 1/2 "process connection with double seal
Front flush diaphragm made of stainless steel 1.4404 (316L)
Measuring ranges from 0 ... +250 mbar to 0 ... +40 bar
Output signal 4 ... 20 mA (2- or 3-wire) or 0 ... 10 V (3-wire)
Quick and easy zero point calibration for relative pressure sensors
For use with higher temperature requirements and in environments with high thermal loads
For media temperatures from -40 ... +180 °C
Cooling section made of stainless steel
Measuring ranges from 0 ... +1 bar to 0 ... +1000 bar
Front flush G 1/2 "process connection, type E with FKM seal
Front flush diaphragm made of stainless steel 1.4404 (316L)
Measuring ranges from 0 ... +100 mbar to 0 ... +60 bar
Output signal 4 ... 20 mA (2- or 3-wire) or 0 ... 10 V (3-wire)
Quick and easy zero point calibration for relative pressure sensors
ecial version for mobile hydraulics with high vibration and EMC resistance
Increased shock resistance of 1000 g according to IEC 68-2-32
Increased vibration resistance of 30 g acc. to IEC 68-2-6 and IEC 68-2-36
Measuring ranges from 0 ... +4 bar to 0 … +4000 bar
Optionally with load-dump protection module
Parallel and independent measurement of pressure and temperature
Temperature measurement with internal temperature sensor
Media temperature -40 ... +125 °C, Temp. measuring range -50 ... +150 °C
Pressure measuring ranges from 0 ... +1 bar to 0 … +1000 bar
Fully welded stainless steel measuring cell and stainless steel housing
Parallel and independent measurement of pressure and temperature
Temperature measurement with external temperature probe
Media temperature -40 ... +125 °C, Temp. measuring range configurable
Pressure measuring ranges from 0 ... +4 bar to 0 … +600 bar
4 ... 20 mA analogue output signals for pressure and temperature
Integrated CANopen interface according to Standard 2.0 A (optional B) with data rates up to 1 Mbit/s
Measuring ranges from 0 ... +1 bar to 0 … +1000 bar
Dry stainless steel measuring cell and compact stainless steel housing
Media temperature -40 … +125 °C
Measuring ranges from 0 ... +40 mbar to 0 ... +250 bar
Output signal 4 ... 20 mA (2-wire) or 0 ... 10 V DC (3-wire)
Dry ceramic measuring cell and robust stainless steel housing
Vacuum-proof and high overload resistance
Total measurement error ≤ 0.2 % FS
Measuring ranges from -1 ... 0 bar to 0 ... +20 bar
Also as intrinsically safe version with ATEX-approval
Frontflush, dry ceramic measuring cell
Vacuum-proof and high overload resistance
Total measurement error ≤ 0.3 % FS